ISO 17735:2019
p
ISO 17735:2019
70406
Indisponible en français

État actuel : Publiée (En cours d'examen)

fr
Format Langue
std 1 151 PDF + ePub
std 2 151 Papier
  • CHF151
Convertir les francs suisses (CHF) dans une autre devise

Résumé

This document specifies a method for the sampling and analysis of airborne organic isocyanates in workplace air.

This document is applicable to a wide range of organic compounds containing isocyanate groups, including monofunctional isocyanates (e.g. phenyl isocyanate), diisocyanate monomers [e.g. 1,6-hexamethylene diisocyanate (HDI), toluene diisocyanate (TDI), 4,4′-diphenylmethane diisocyanate (MDI), and isophorone diisocyanate (IPDI)], prepolymers (e.g. the biuret and isocyanurate of HDI), as well as chromatographable intermediate products formed during production or thermal breakdown of polyurethane.

In mixed systems of HDI and IPDI products, it is impossible to identify and quantify low levels of IPDI monomer using this document, due to coelution of IPDI monomer with HDI-uretidinedione.

It is known that the method underestimates the oligomer in MDI-based products. Total isocyanate group (NCO) is underestimated in MDI-based products by about 35 % as compared to dibutylamine titration.

The method has been successfully modified to be used with LC-MS-MS for TDI monomer using an isocratic 70 % acetonitrile/30 % 10 mM ammonium formate mobile phase.

The useful range of the method, expressed in moles of isocyanate group per species per sample, is approximately 1 × 10−10 to 2 × 10−7. The instrumental detection limit for the monomers using both ultraviolet (UV) detection and fluorescence (FL) detection is about 2 ng monomer per sample. The useful limit of detection for the method using reagent impregnated filters is about 10 ng to 20 ng monomer per sample for both UV and FL detection. For a 15 l sample, this corresponds to 0,7 µg/m−3 to 1,4 µg/m−3. For impinger samples, which require solid phase extraction, experience has shown that the useful limit of detection is about 30 ng to 80 ng monomer per sample.

Prévisualiser 

Prévisualiser cette norme sur notre Plateforme de consultation en ligne (OBP)

Informations générales

  •  : Publiée
     : 2019-04
    : Norme internationale en cours d'examen systématique [90.20]
  •  : 2
  • ISO/TC 146/SC 2
    13.040.30 
  • RSS mises à jour

Vous avez une question?

Consulter notre FAQ

Service à la clientèle
+41 22 749 08 88

Horaires d’ouverture:
De lundi à vendredi - 09:00-12:00, 14:00-17:00 (UTC+1)